When you have all 3 temps you know hottest to coldest and can adjust your smoker temp as needed to average them out should the PID probe be getting dripped on or touching cold meat or pans, etc. I put the PID probe dead center under lowest rack and now I get temp readings accross the whole rack to interperate any weird temps across the rack.
#Masterbuilt electric smoker control panel fell off free
We have a great online selection at the lowest prices with Fast & Free shipping on many items. I have run a 4 probe wireless thermometer and I put a probe on the far back left of lower rack and upfront right side of lower rack. Get the best deals for masterbuilt electric smoker control at.

You will still have to fiddle with everything until you understand your smoker's new performance but this is true with any kind of smoker no matter what. You can get true consistency out of your smoker temp and you never have to fear melting out fat from sausage or bacon, or over cooking jerky when you want to dehydrate it! :) No more temp swings, no more failing to hit the max 275F temp, no more erratic temp behavior! Digital Control Panel Kit for electric smokers. Also had temperature issues - the MES would not heat up to the temperarture I set on the control panel. Provided you clip the temp probe to the bottom of the lowest smoker rack for it to read the temps fast. I've got a Masterbuilt 30 Gen 1 w/RF, and had issues recently w/the control panel flaking out (turning off on its own, LEDs dying on the display). PID controllers will hold within 1-3 degrees of the set temp you enter. Note that you can remedy those issues and still return your Masterbuilt electric smoker to working order. Moisture and outlet issues can also cause the electric smoker to malfunction. Control Panel Kit for 30 inch electric smokers. DONE! The PID now feeds power on/off to the MES to hit and hold the set temp you entered. If your Masterbuilt electric smoker keeps shutting off, the issue could be related to an improperly connected probe. Whether you’re a beginner or a competition-ready pro, craft your backyard masterpiece without the hassle of propane.

This smoker has a glass window door and a remote that will let you control and monitor your smoker. Clip PID temp probe to the bottom of the lowest smoker rack and enter the set smoker temp you want into the PID. Masterbuilt Sportsman Elite 40 Inch Electric Smoker has it all. Plug MES into PID controller and plug PID controller into wall (PID now feeds power from wall to MES heating elementģ. This means power feeds to the heating element from the MES plug.Ģ.

Do the simple rewire (cut ends of 4 wires, use 2 wire nuts to splice proper ends together to make 2 whole wires) - very simple.